Simulation Engine Overview

Simulation Methodology​

Module: insight (always on) | Role: Any member | Licence: Free+

Engine: Monte Carlo simulation with 15-minute intervals (96 per day).

Time Resolution​

ConstantValueDescription
INTERVALS_PER_HOUR415-minute intervals
INTERVALS_PER_DAY9624 hours x 4 intervals
INTERVAL_DURATION_HOURS0.2515 minutes in hours
INTERVAL_DURATION_MINUTES1515 minutes

The 15-minute resolution aligns with:

  • Australian NEM (National Electricity Market) settlement periods
  • UK half-hourly settlement (Elexon) — maps cleanly to 2x 15-minute intervals
  • Standard smart meter data granularity in UK and US markets
  • Industry standard for energy trading intervals

Times are specified as HH:MM strings and converted to interval indices (e.g. "06:00" → interval 24, "14:30" → interval 58).

Limitation: 15-minute resolution cannot capture sub-minute transients (inrush currents, frequency response) or appliance-level events (kettle spikes, oven cycling). Grid stability studies requiring 1-second or faster resolution are out of scope.

Approach​

  • Each EV is individually sampled from probability distributions (plug-in time, connection duration, energy required, charge rate, ready-by deadline)
  • Quantized charging: energy = ceil(energy_required / charge_rate x 4) intervals
  • Every EV receives its full required charge — flexibility only changes WHEN, never HOW MUCH
  • Load profiles (households, commercial, data centres) are deterministic — no randomness. Only EV charging and thermostat DR use stochastic simulation.

N+2 Day Simulation​

The engine internally simulates N+2 days and returns the middle N days:

DayPurpose
Day 0Cold-start warm-up — allows EVs plugging in on day 0 to complete charging
Days 1 to NOutput days — these are returned to the user
Day N+1Cleanup/warm-down — allows EVs from day N to shift charge forward without losing energy at the boundary

When a display window offset is used (e.g. noon-to-noon), the engine extends to N+3 internal days to ensure complete coverage.

Distributions Summary​

ParameterDistributionDefault Parameters
Plug-in timeBimodal GaussianEvening 19:00 (75%, sigma=2h), Morning 07:00 (25%, sigma=1h)
Connection durationLog-normalMode ~14h, sigma=0.25, max 24h
Energy requiredNormalmu=21 kWh, sigma=15 kWh, max 100 kWh
Charging rateDiscrete7 kW (70%), 3 kW (20%), 11 kW (10%)
Ready-by timeCategorical07:00 (40%), 08:00 (30%), flexible (30%)

See the EV Smart Charging page for full distribution detail, sources, and limitations.

Unified Scenario Model​

Each scenario contains both load cohorts and flexible asset cohorts. The simulation produces:

  • base_profile: all assets simulated at FIXED (unmanaged) behavior — the "do nothing" baseline
  • flexed_profile: assets simulated at their assigned flexibility_mode — what the grid actually sees
  • Component traces: individual contribution of each cohort

Flexibility Modes (per-cohort)​

FlexibilityModeDisplay NameTool AliasesBehavior
FIXEDUnmanaged"unmanaged", "none", "baseline"Natural behavior, no control
MANAGEDManaged"passive", "active", "dr", "curtail", "diversify"Responds to DR signals or curtailment windows
OPTIMIZEDOptimized"optimized", "balance", "vpp", "aggregated"Full load balancing against base_profile

For EV-specific load shaping modes (NONE/DIVERSIFY/BALANCE) and smart charging levels (L0-L3), see EV Smart Charging.

Performance​

Simulation scales linearly with vehicle count:

  • NONE mode: ~0.2s for 10,000 vehicles
  • BALANCE mode: ~0.4s for 10,000 vehicles

The random seed controls reproducibility, but different seeds produce statistically similar results for large fleets (>100 vehicles).

Sign Convention​

  • Positive = consumption/import from grid (includes pre-charge/rebound for thermostat DR)
  • Negative = generation/export to grid or load reduction (includes thermostat DR reduction phase)

Limitations​

  • Single-day simulations do not capture week-level patterns (weekend vs weekday differences)
  • No grid constraints modeled — simulations show energy flows, not voltage/frequency impacts
  • Fixed 15-minute resolution — all assets share the same time grid with no adaptive time-stepping
  • The simulation models energy scheduling, not power quality or phase balance