Battery Storage
Module:
insight(always on) | Role: Any member | Licence: Free+
Model: Deterministic charge/discharge cycles with configurable scheduling or optimal dispatch.
Default Specifications
| Parameter | Value | Notes |
|---|---|---|
| Capacity | 12.5 kWh | Usable capacity |
| Max charge/discharge rate | 5 kW | Symmetric |
| Discharge duration | 2.5 hours | At max rate |
| Charge duration | 2.75 hours | Longer due to efficiency losses |
| Round-trip efficiency | 90% | AC-to-AC |
| Min SoC | 10% | Reserve for backup |
| Max SoC | 100% | Full charge allowed |
| Initial SoC | 50% | Starting state of charge |
Source: Values represent a median residential battery system in 2024-2025, informed by Tesla Powerwall (13.5 kWh), Enphase IQ (5/10/15 kWh), and BYD HVS (5.1-12.8 kWh). 90% round-trip efficiency is conservative; modern lithium-ion systems achieve 89-95%.
Flexibility Modes
Unmanaged (FIXED)
Scheduled discharge/charge at fixed times:
discharge_start: default"19:00"(evening peak)charge_start: default"12:00"(midday solar)
Optimized (OPTIMIZED)
Aggregated dispatch using a sliding-window algorithm:
- Scans the scenario's
base_profileto find the highest-load window (optimal discharge) - Scans for the lowest-load window (optimal charge)
- Dispatches all batteries in the cohort to maximize peak reduction
This mode is scenario-aware — it targets the actual load shape, not a fixed schedule.
Limitations
- Single battery model; does not capture multi-battery or hybrid configurations
- Degradation over lifetime is not modeled (efficiency and capacity assumed constant)
- Temperature effects on performance are not captured
- Does not model partial state-of-charge constraints beyond min/max SoC