Skip to main content

Supported Utilities

Module: insight (always on) | Role: Any member | Licence: Free+

Gridbase includes 17 utility adapters that fetch hosting capacity data from public utility Integration Capacity Analysis (ICA) portals.

Adapter Registry​

California​

UtilityIDCircuitsSubstationsVoltageGen DataDemand Data
PG&Epge3,025715YesYesYes
SDG&Esdge524107YesYesYes
SCEsce3,287466YesYesNo

New York​

UtilityIDCircuitsSubstationsVoltageGen DataDemand Data
ConEdconed1,02630YesYesYes
NYSEGnyseg578373YesYesYes
RG&Erge207143YesYesYes
PSEG Long Islandpseg_long_island921157YesYesNo
Orange & Rocklandorange_rockland27180YesYesYes
Central Hudsoncentral_hudson13569YesNoNo

New England​

UtilityIDCircuitsSubstationsVoltageGen DataDemand Data
Eversource CTeversource_ct479512YesYesNo
Eversource MAeversource_ma31692PartialNoNo
Eversource NHeversource_nh272656YesYesNo
United Illuminatingunited_illuminating24829YesYesNo

Mid-Atlantic & Other​

UtilityIDCircuitsSubstationsVoltageGen DataDemand Data
National Grid MAnational_grid_ma967242YesYesNo
BGEbge37,704 (grid cells)—NoNoNo
PEPCOpepco78090PartialNoNo
Xcel Energyxcel3,078488YesYesNo

Totals: 53,818 circuits, 4,249 substations

Data Fields​

Each feeder/circuit record includes (where available):

FieldDescriptionCoverage
Feeder ID / NameUnique circuit identifierAll utilities
Latitude / LongitudeWGS84 coordinatesAll utilities
Total Capacity (MW)Feeder rated capacityAll utilities
Available Capacity (MW)Remaining headroom for new DERAll utilities
Constraint TypeThermal, voltage, or protectionMost utilities
Utilization %Current load as fraction of capacityMost utilities
Substation NameParent substationMost utilities
Voltage (kV)Feeder voltage class11 utilities
Existing DG (MW)Distributed generation already connected10 utilities
Peak Demand (MW)Historical peak load8 utilities

Capacity Levels​

LevelThresholdColor
High>= 2 MW availableGreen
Medium0.5-2 MW availableAmber
Low< 0.5 MW availableRed
UnknownNo dataGray

Refresh Frequency​

Utility ICA data is updated quarterly by utilities. Gridbase fetches are triggered manually or via scheduled jobs. HIFLD transmission data is updated annually.